| Model Number |
Lumen Output |
# Lamps Operated | Wattage Number | Lamps Operated | Full Warranty | Features | ||
| T U B U L A R |
S96FSD | Up to 3500 | 1 or 2 | 17W to 215W | (2' - 8') T8, T9, T10, T12, & (4 - pin) twin, quad, or triple twin-tube & long compact fluorescent lamps |
5 Years | Self Diagnostic controller with self-testig feature for full illumination applications. | |
| S96F |
3500 - 1000
|
Full illumination, superior grade two-lamp operation
|
||||||
| S93F |
3400 to 2700
|
2 or 3
|
32 W - 55 W
|
2 W (4’) T8 and (4 - pin) long compact
|
For instant start, parallel AC ballast only.
|
|||
| S60FCW |
Up to 1500 lumens @ 25°C
|
1 or 2
|
17W to 215W
|
T8, T9, T10 and T12 fluorescent lamps
|
Cold Weather: Operation to -20°C. Suitable for use with sealed & gasketed fixtures. |
|||
| S60FSD |
1400 - 1100
|
(2' - 8') T8, T9, T10, T12, &
(4 - pin) twin, quad, or triple twin-tube & long compact fluorescent lamps |
Self Diagnostic microcontroller with self testing feature
|
|||||
| S60F-UNV |
1350 to 1000
|
13 W to 215 W
|
120 through 277 VAC, 50 or 60 Hz Universal Voltage.
|
|||||
| S60F |
1400 - 1100
|
17W to 215W
|
Specification-grade two lamp operation
|
|||||
| S66F |
700 - 600
|
13 W to 215 W
|
(2' - 8') T8, T9, T10, T12, &
(4 - pin) long compact fluorescent lamps |
3 Years
|
Economical two-lamp operation
|
|||
| S66F-UNV |
17W to 215W
|
120 through 277 VAC, 50 or 60 Hz Universal Voltage.
|
||||||
| S45F |
1
|
Two-hour operation with one 17 W to 40 W lamp
|
||||||
| S40F |
600 -500
|
17W to 40W
|
(2' - 4') T8, T9, T10, T12, &
(4 - pin) long compact fluorescent lamps |
2 Years
|
Economical one-lamp operation
|
|||
| S35F |
450 - 350
|
Commodity priced one-lamp operation
|
||||||
| Model Number |
Lumen Output |
# Lamps Operated | Wattage Number | Lamps Operated | Full Warranty | Features | ||
| T H I N S E R I E S |
S76T | 1325 - 650 | 1 | 13W to 55W | T5 high output & standard, T8 &(4-pin) long compact fluorescent lamps | 5 Years | High lumen output, low-profile design for ballast channel installation in space-limited fixtures. |
|
| S74T | 700 - 390 | 14W to 55W | "THIN" emergency ballast for standard & high output T5 & T8 lamps | |||||
| S72T | 520 - 370 | 14W to 28W | T5 standard lamps | "THIN" emergency ballast for standard T5 lamps. | ||||
| S70T | 450 - 350 | 16W to 40W | (2' - 4') T8, T9, T10, T12 & (4-pin) compact fluorescent lamps | 3 Years | "THIN" emergency ballast for one-lamp operation | |||
| S60T |
1300 - 750
|
1 or 2 | 17W to 215W | (2' - 8') T8, T9, T10, or T12 fluorescent lamps & (4-pin) twin, quad, and triple twin-tube compacts |
5 Years | Low profile ballast for T8-T12 lamps where fixture uses narrow/shallow ballast channel. | ||
| Model Number |
Lumen Output |
# Lamps Operated | Wattage Number | Lamps Operated | Full Warranty | Features | ||
|
S70C | 1300 to 600 | 1 | 32W to 70W | Higher Wattage, 32, 42, 57 & 70W long compact fluorescent lamps (4-pin) |
5 Years | Long compacts (4-pin) & end of lamp life circuitry compatible | |
| S44CSD | 1000 - 350 | 1 or 2 | 13W to 55W | (4 - pin) twin, quad, triple twin-tube or long compact & (2-8') T8, T9, T10, T12 fluorescent lamps | Self-Diagnostic microcontroller with self-testing feature for compact fluorescent lamps. |
|||
| S42CCW | Up to 1250 @25°C |
1
|
13 W to 42 W |
Cold Weather: Operation to -20°C. Suitable for use with Sealed and Gasketed fixtures. |
||||
| S42C | 1000 - 325 | 1 or 2 | 16W to 215W | 2 Years | Operates 1 or 2 lamps without integral starter at higher lumen output | |||
| S28C | 750 - 300 | 6W to 42W | (4 - pin) twin, quad, or triple twin-tube | Operates 1 or 2 lamps without integral starter | ||||
| S26C | 950 - 450 | 10W to 26W | (2 - pin) twin, quad or triple twin-tube | Operates 1 or 2 lamps with integral starter at high lumen output | ||||
| S30C | 650 - 300 | 1 | (2 - pin) quad or triple twin-tube | Operates one lamp with integral starter | ||||
| S13C | 625 - 200 | 5W to 13W | (2 - pin) twin or quad tube | Operates one lamp with integral starter | ||||
| Model Number |
Features | |||||||
| D A M P L O C A T I O N |
S60FCW | Also suitable for damp locations | ||||||
| S60F-UNV | Also suitable for damp locations | |||||||
| S60FDL | Damp version of S60F | |||||||
| S66FDL | Damp version of S66F | |||||||
| S40FDL | Damp version of S40F | |||||||
| S42CCW | Also suitable for damp locations | |||||||
| S28CDL | Damp version of S28CDL | |||||||
| S26CDL | Damp version of S26CDL | |||||||
| S13CDL | Damp version of S13DL | |||||||
| Model Number |
Lumen Output |
# Lamps Operated | Wattage Number | Lamps Operated | Full Warranty | Features | ||
| O T H E R |
PSM | The PSM works with a generator or central inverter system to provide emergency lighting | 5 Years | Power Switching Module for generator supplied or central inverter supplied systems |
||||
| SBD20 | Lighting Control Relay works with a generator or central inverter system to provide emergency lighting to a switched 20 A circuit. | 5 Years | OPerates a 20-amp circuit load of fluorescent, incandecent & HID lamps. | |||||
| S48F | 3100 to 1000 | 1 or 2 | 13W to 215W | (2'-8') T8, T9, T10, T12 & (4-pin) twin, quad, or triple twin-tube & long compact fluorescent lamps | 1 Year | Full back-up illumination from 48 VDC Central Battery Supply. | ||
See Specification Sheets for details.
All models are:
- UL Listed for factory or field installation
- 120/277VAC, 60 Hz
- Exceed NEC, LSC and UL 90-minute requirements
- Contain high-temperature nickel-cadmium batteries that are maintenance-free and fully recharge within 24 hours
- Can be installed inside, on top of, or remote from fixture, except S96F, compact and Thin Series models - see individual model spec sheets for complete details